Y Series IE3 Rib-Cooled High-Voltage Asynchronous Motors

Y Series IE3 Rib-Cooled High-Voltage Asynchronous Motors

The Y Series energy-efficient high-voltage motors feature at the innovative external ribbed cooling structure. It is scientifically optimized the rib layout enhancing the natural convection and significantly improving the cooling efficiency for various complex industrial environments. Covering rated voltages of 6 kV and 10 kV with the power range at 110–2800 kW, this series combines the optimized electro-magnetic design with the manufacturing techniques proven. It meets the GB30254 Grade 3 Efficiency Standard while offering excellent value. The rib-cooled design simplifies the cooling system, reducing overall complexity and maintenance needs, making it to be the ideal, cost-effective and reliable choice for the industrial power system, especially where the space is limited

The Y Series IE3 rib-cooled high-voltage asynchronous motors feature an innovative external ribbed cooling structure, achieving a compact design while ensuring effective heat dissipation. Suitable for various industrial drive applications, this series offers a cost-effective and reliable power solution, balancing operational efficiency with cost control.

Key Features

Featuring an innovative external ribbed cooling structure, this motor series utilizes a scientifically optimized rib layout to enhance natural convection heat dissipation, significantly improving cooling efficiency for diverse and complex industrial environments. With rated voltages covering 6kV and 10kV, and a power range of 110–2800 kW, the series combines optimized electromagnetic design with mature manufacturing processes. It meets the Grade 3 efficiency standard of GB30254 (IE3 equivalent) while achieving excellent cost-performance. The rib-cooled design simplifies the cooling system structure, reducing overall equipment complexity and maintenance requirements. It stands as an ideal choice for industrial drives where space is limited and a balance of economy and reliability is paramount.
Efficient Rib-Cooled Design:​ The external reinforced rib structure improves natural cooling efficiency, reducing reliance on auxiliary cooling systems and lowering overall system complexity and energy consumption.
Economical Efficiency:​ Meets the GB30254 Grade 3 energy efficiency standard, achieving an optimal balance between performance and cost, which significantly reduces long-term operating energy consumption and maintenance expenses.
Compact & Reliable Structure:​ More space-saving compared to traditional cooling methods, offering greater installation adaptability, saving valuable floor space, and facilitating layout in confined areas.
Easy Maintenance & Durability:​ With no complex cooling piping, daily upkeep is straightforward. High operational reliability effectively minimizes downtime and enhances overall equipment utilization efficiency.
Strong Environmental Adaptability:​ The totally enclosed protective design effectively guards against dust and moisture ingress, adapting to various industrial environments and ensuring stable operation under diverse working conditions.

Technical Specifications

Power Range:​ This series covers a rated power range from 110 kW to 2800 kW. With reasonable power gradation, it meets the drive requirements of various industrial equipment sizes, making it suitable for most medium to large-scale applications such as fans, pumps, and compressors.
Rated Voltage:​ Supports two industrial high-voltage levels: 6 kV and 10 kV. This complies with mainstream domestic and international power supply system standards, allowing direct connection to existing grids and reducing system modification costs.
Efficiency Class:​ Fully complies with the GB30254 Grade 3 energy efficiency standard (IE3 equivalent). Utilizing optimized electromagnetic design and low-loss materials and processes, it maintains high-efficiency operation within typical load ranges, helping to reduce long-term operating electricity consumption for users.
Power Factor:​ The rated power factor is 0.85–0.89, offering good grid compatibility. This reduces the need for reactive power compensation and optimizes the operating efficiency and stability of the power supply system.
Protection Level:​ Features IP54 or IP55 protection ratings. The totally enclosed structure effectively prevents the ingress of dust and water jets, making it suitable for industrial environments with moderate dust or humidity levels.

Successful Stories

Motor Selection Guide and FAQ

Motor Selection Guide
1. Define Basic Parameters
Power & Speed:​ 
Determine the required rated power based on load characteristics and define the motor pole count and speed range according to your equipment’s operational speed.
Voltage & Frequency:​
Confirm your power supply standard (e.g., 380V/50Hz, 480V/60Hz). Custom designs are available for special voltage requirements.
Mounting Type:​
Specify IEC standard mounting (e.g., B3, B5, B14). Custom the flanges & bases are also supported.
2. Consider Operating Environment
Protection Rating (IP):​
IP55 for standard environments. IP65 is recommended for damp or dusty conditions. Hazardous areas require Ex D/Ex E certifications.
Insulation Class:​
Class F (155°C) for general use. Class H (180°C) insulation is advised for high-temperature environments.
Cooling Method:​
Self-ventilated (IC411) for standard applications. Forced air or water cooling is available for enclosed spaces or high-power-density scenarios.
3. Match Load Characteristics
Starting Torque:​
Consider starting torque for fan/pump loads. Verify locked-rotor torque for conveying equipment.
Duty Cycle:​
Standard motors are suitable for continuous operation (S1). Frequent start-stop cycles (S5) require reinforced bearings and insulation.
Efficiency Requirement:​
Select IE3/IE4/IE5 efficiency classes based on annual operating hours. Ultra-premium efficiency (IE5) motors offer the lowest total cost of ownership for long-running applications.
Get Your Custom Solution & Fast Quote. Our Engineers Are Ready to Help.
Contact Us for the Precise Solution
Provide your equipment parameters, load profile, environmental conditions, and application details.
Receive the complimentary motor selection calculation, the energy efficiency analysis report, and the 3D model.
We support sample testing and operational simulation for validation.

Scroll to Top